Unidata IDV Workshop for version 7.0u1  > Advanced Topics  > Configuring the IDV  
4.1.2 Editing Parameter Display Defaults
In the previous section we covered how to create new color tables. We saw that
for a temperature field there were certain default values for the
color table and range that is used. In this section we will discuss how to
change
this default behavior using the Parameter Defaults Editor.
  -  If you haven't done so already load in some example data and create a
      display of 
temperature. 
  
    -  Load in  the 
Sample RUC Data data source.
            
     
    -  Create a 
Color-Shaded Plan View display with a temperature parameter. 
            
 
    -  Note that the color table used is the Temperature color table
        and that the range is -90 to 45.
 
  
  -  Open up the 
Parameter Defaults Editor  by selecting the
       menu item. 
  -  There should be two tabs shown: 
User Defaults
      and System Defaults. The first tab shows the
      user editable parameter defaults. The second  tab shows the system
      defaults. 
  -  Click on the 
System Defaults tab. 
  -  The first column shows the parameter name pattern that is used to match
      the
      parameter.
      More about patterns.
 
  -  Change the default color table and range for 
temperature
      parameters.
  
    -  Scroll down to the row that holds the 
temp parameter. 
    -  Right click on this row and select
        .
    
 -  You should now see the 
temp row in the
        User Defaults tab and Parameter Defaults dialog shown.
     -  Change the default color  table by selecting the
         menu item.
    
 -  Change the range to  -45 and 45.
    
 -  Save your changes by clicking the 
OK button. 
  
   -  Test out this change.
 
  
    -  Remove your displays by selecting the
        
        menu item.
 
    -  Create a 
Color-Shaded Plan View display with a temperature parameter. 
            
 
    -  You should see the new Comfort color table and range being
        used.
 
  
  -  What about setting defaults for new parameters?
  
     -  Create a Color-Filled Contour Plan View using the
relative humidity at fixed height above ground.
      -  Bring up the Contour Properties Editor for the display and change the interval to 10  press 
OK.
      -  Change the range to be 0-100
     
 -  Change the Color Table to the 
     
 -  From the display's   menu choose 
     
 -  The Parameter Defaults dialog is shown. Press 
OK.
      -  Remove displays and recreate the above display. All should be better now.
  
 
 
 
 
 
Unidata IDV Workshop for version 7.0u1  > Advanced Topics  > Configuring the IDV